Product Cable Accessories Capcon OA-W Series Multiple
Capcon Multiple
A single CAPCON connector accomdates up to 4 cables simultaneously

Features
  • Secuerly clamps and protects four cables simultaneously through one CAPCON Multiple
  • Significantly saves the labor to drill entry holes and provides space saving as well
Select the most appropriate type according to your use environment
  • Use oil proof type were oil or oil mist is present
  • Weatherproof type for outdoor usage
    Note : The weatherproof type is recommended for all indoor applications with the exception of environments where oil or oil mist is present
  • Application
    • Up to four wires such as sensor cables and etc. can be clamped by one CAPCON, which lightens rhe drilling works and results in space-saving.
    • Apply to wire outlets where CVD or CVT cables are used such as underground tunnels, construction fields and etc.
    Instructions

    1. Drill the entry hole according to the specification chart below.

    2. Install the CAPCON according to the appropriate application listed below.

    < For Electrical Service Panel Installation >
    Remove and retain the lockunt and insert the CAPCON connector into the entry hole and tighten it from the back using the locknut.

    < Pre-thereaded Holes on Limite Switches etc, >
    Remove and discard the locknut. Screw the CAPCON connector in to the existing threads to tighten.

    3. Cable Insertion

    Loosen the dome nut and insert the cable through the connector as shown in 1 and 2 in the figure to the right











    4. Secure Cable

    Tighten the dome nut to fasten cable securely

    Inserts - [comes with 4 hole products]
    2 blanks inserts are included with 4 hole products as a standard accessory (not avaliable in 2 or 3 hole products). The blank Inserts should be placed in unused holes when less than 4 cables are entering the connector.

    Specification

    Type
    Applicable Wire D.M.(mm)
    Qty in Bores
    Bore D.M.(mm)
    Thread
    Applicable Plate Thickness
    Ambient Temperature
    Qty in Package
    O6-224A-W1
    1.7~2.2
    4
    21
    PF 1/2
    4 mm or less
    -25 íC
    ~
    80 íC
    20/Box
    OA-W16-404
    3~4
    OA-W16-602
    5~6
    2
    OA-W22-604
    5~6
    4
    28
    PF 3/4
    6mm or less
    10/Box
    OA-W22-704
    6~7
    OA-W28-102
    9.8
    2
    34
    PF 1
    5.5 mm or less
    10/Box
    OA-W28-103
    3
    OA-W36-132
    13.5
    2
    42
    PF 1 ¼
    7.5 mm or less
    10/Box
    OA-W36-133
    3

    Part Desctiption and Materials



    Cautions for use and storage

    Use and storage of these products in the following conditions is not recommended
    1). Outside an appropriate temperature range
    2). In a strong acidic or organic solvent (chloride ethyl, chloride methyl, cresol etc,) environment.
    3). In damp atmosphere of where ozone is present
    < Oil proof Type (Rubber color black) >
    1). Not appropriate for use under direct and continuous sunlight
    2). Use oil proof type were oil or oil mist is persent
    *Use a weatherproof type for applications other than oil and oil mist environments
    < Weatherproof Type (Rubber color black) >
    1).Weatherproof type for outdoor usage
    Note : The weatherproo type is recommended for all indoor applications with the exception of environments where oil or oil mist is present

    < Note >Consult us, prior to use, with any special application questions.
     